T
13

My controller board kept throwing a random fault code 47 last Tuesday.

Turns out a loose wire on the door lock relay was grounding out against the cabinet frame, took me 3 hours to trace it with a meter; has anyone else had phantom faults from vibration loosening terminal screws?
2 comments

Log in to join the discussion

Log In
2 Comments
wilson.jana
Did you find any other screws loose once you got in there, or was it just that one terminal that worked itself free?
3
john_sullivan2
Man did you actually find just one loose screw? That's wild @wilson.jana because usually with those older terminals the whole bracket is a mess inside. I had a similar situation last year where I thought it was one connection but the whole grounding plate was basically rattling around back there. First time I popped the cover off I was shocked at how many things were just barely hanging on. So yeah, pretty lucky it was just that one terminal honestly.
8